Y.1564 not running in Steps

Document created by viavisupport on Jan 17, 2017
Version 1Show Document
  • View in full screen mode
MTS/TB5800/6000A/8000E Y.1564 testing not stepping up.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           

Problem Overview

MTS/TB5800/6000A/8000E Y.1564 testing not stepping up. Three steps were configured but they did not appear to execute.

Resolution

The Y.1564 Samcomplete test, on the bert module, only steps up if the circuit cannot run at the designated CIR. It the circuit runs clean at CIR it skips the steps up. This is normal operation.