Unable to start traffic on the HST Ethernet Layer 2 terminate test.

Document created by viavisupport on Jan 17, 2017
Version 1Show Document
  • View in full screen mode
Unable to start traffic on the HST Ethernet Layer 2 terminate test.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           

Problem Overview

Unable to start traffic on the HST Ethernet Layer 2 terminate test. It is greyed out and cannot be selected.

Resolution

Unable to Start traffic usually occurs because the link is not active. Check the LED results category under the display tab to determine if the link active is illuminated. If it is not then check the unit's auto negotiation settings and make sure it matches the configuration of the port you are plugging into on the network. If Ethernet optical testing check to ensure the correct type of optics are installed and that your laser is turned ON. If Ethernet electrical testing check to make sure that you are connecting to the top port on the left side of the module labelled R/T 1. The electrical port on the top of the HST mainframe is not used for traffic generation testing.
1 person found this helpful

Attachments