40G Certifier Probe mismatch error on reference.

Document created by viavisupport on Feb 21, 2017
Version 1Show Document
  • View in full screen mode
I am trying to perform a copper reference on my Viavi 40G Certifier and getting a probe mismatch error message.                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                           

Problem Overview

I am trying to perform a copper reference on my Viavi 40G Certifier and getting a probe mismatch error message.

Resolution

You cannot perform a reference with 2 channel adapters. A reference needs to be done with a permanent link adapter on the local unit and a channel adapter on the remote using one permanent link cable.

Attachments

    Outcomes